ESU N, H0, 0 - 50094 - Digital control unit (1) - ECoSDetector Feedback Module





€1 |
|---|
Catawiki Buyer Protection
Your payment’s safe with us until you receive your object.View details
Trustpilot 4.4 | 143539 reviews
Rated Excellent on Trustpilot.
ECoSDetector Return Feedback Module with 16 digital inputs, including 4 RailCom, compatible with N, HO and 0 scales, in new condition, original packaging, catalog number 50094.
Description from the seller
ECoSDetector Feedback Module, 16 digital inputs of which 4 are RailCom.
Current sensor
The ECoSDetector can monitor 16 track sections. The inputs can be individually switched between switch input (ground input) or current sensor using a jumper. The ECoSDetector can therefore be used universally on all rail systems and is therefore the first choice for all two-wire controllers. Since the inputs, each of which may carry a maximum of 3A, can be supplied in two separate power groups, each ECoSDetector can control up to two booster circuits. Optocouplers ensure reliable detection.
Detection of train numbers
In addition to conventional track occupancy detectors, the ECoSDetector can specially monitor four of the 16 track sections: With RailCom technology ("local detector"), it can be determined on these sections not only whether a train is running, but even which train it is (train-number detection). Of course, you need RailCom-compatible locomotive decoders for this.
Smart
Knowing exactly which train is on a section, in combination with the ECoS turnout module, enables new functions: The barriers at a level crossing can automatically be lowered, for example, or trains search for a free track in the yard. In doing so, the switch inputs or track occupancy detectors are electronically "unlinked" to ensure reliable feedback, even with a faulty contact or heavily dirty rails.
ECoSlink connection
Each ECoSDetector is directly connected to the control unit via the ECoSlink bus. All ECoS command stations and all Central Station Reloaded with ESU Update are suitable. The galvanic isolation of the bus system and the command station guarantees the highest operational safety and a safe transmission to the command station. All ECoS detectors are automatically recognized in the central and integrated into the operating sequence. The configuration of the devices takes place conveniently and easily directly on the command station and can also be performed after installation.
Future built-in
The control software of each ECoSDetector can be updated and extended with additional features if needed: The required "update" is carried out completely automatically when needed by the control panel. Thus your ECoSDetector is always up-to-date with the latest technology.
Photos are part of the description
If defective within 1 month from the Netherlands, return at no cost.
All packages are sent by registered mail and insured.
Seller's Story
ECoSDetector Feedback Module, 16 digital inputs of which 4 are RailCom.
Current sensor
The ECoSDetector can monitor 16 track sections. The inputs can be individually switched between switch input (ground input) or current sensor using a jumper. The ECoSDetector can therefore be used universally on all rail systems and is therefore the first choice for all two-wire controllers. Since the inputs, each of which may carry a maximum of 3A, can be supplied in two separate power groups, each ECoSDetector can control up to two booster circuits. Optocouplers ensure reliable detection.
Detection of train numbers
In addition to conventional track occupancy detectors, the ECoSDetector can specially monitor four of the 16 track sections: With RailCom technology ("local detector"), it can be determined on these sections not only whether a train is running, but even which train it is (train-number detection). Of course, you need RailCom-compatible locomotive decoders for this.
Smart
Knowing exactly which train is on a section, in combination with the ECoS turnout module, enables new functions: The barriers at a level crossing can automatically be lowered, for example, or trains search for a free track in the yard. In doing so, the switch inputs or track occupancy detectors are electronically "unlinked" to ensure reliable feedback, even with a faulty contact or heavily dirty rails.
ECoSlink connection
Each ECoSDetector is directly connected to the control unit via the ECoSlink bus. All ECoS command stations and all Central Station Reloaded with ESU Update are suitable. The galvanic isolation of the bus system and the command station guarantees the highest operational safety and a safe transmission to the command station. All ECoS detectors are automatically recognized in the central and integrated into the operating sequence. The configuration of the devices takes place conveniently and easily directly on the command station and can also be performed after installation.
Future built-in
The control software of each ECoSDetector can be updated and extended with additional features if needed: The required "update" is carried out completely automatically when needed by the control panel. Thus your ECoSDetector is always up-to-date with the latest technology.
Photos are part of the description
If defective within 1 month from the Netherlands, return at no cost.
All packages are sent by registered mail and insured.

